6VAE

Mono-ubiquitinated Fanconi Anemia ID complex bound to ICL DNA


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg35.303
r_dihedral_angle_3_deg16.695
r_dihedral_angle_4_deg13.481
r_dihedral_angle_1_deg6.925
r_scangle_other5.82
r_long_range_B_refined5.225
r_long_range_B_other5.225
r_mcangle_it4.002
r_mcangle_other4.002
r_scbond_it3.805
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg35.303
r_dihedral_angle_3_deg16.695
r_dihedral_angle_4_deg13.481
r_dihedral_angle_1_deg6.925
r_scangle_other5.82
r_long_range_B_refined5.225
r_long_range_B_other5.225
r_mcangle_it4.002
r_mcangle_other4.002
r_scbond_it3.805
r_scbond_other3.805
r_mcbond_it2.631
r_mcbond_other2.631
r_angle_other_deg1.537
r_angle_refined_deg1.42
r_chiral_restr0.137
r_bond_refined_d0.01
r_bond_other_d0.007
r_gen_planes_refined0.007
r_gen_planes_other0.004
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Mono-ubiquitinated Fanconi Anemia ID complex bound to DNA
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles301158
Reported Resolution (Å)3.6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (3S4W)
Refinement SpaceRECIPROCAL
Refinement ProtocolOTHER
Refinement TargetR-factor
Overall B Value150
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)51
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
CTF CORRECTIONCTFFIND4
MODEL FITTINGO
INITIAL EULER ASSIGNMENTRELION3
MODEL REFINEMENTREFMAC5
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION