SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
13D HNCA1 mM U-13C-15N Yih190% H2O/10% D2O30 mM7.21 atm298Bruker AVANCE 700
23D HNCACB1 mM U-13C-15N Yih190% H2O/10% D2O30 mM7.21 atm298Bruker AVANCE 700
33D 1H-15N NOESY1 mM U-13C-15N Yih190% H2O/10% D2O30 mM7.21 atm298Bruker AVANCE 700
42D 1H-15N HSQC1 mM U-13C-15N Yih190% H2O/10% D2O30 mM7.21 atm298Bruker AVANCE 700
52D 1H-13C HSQC aliphatic1 mM U-13C-15N Yih190% H2O/10% D2O30 mM7.21 atm298Bruker AVANCE 700
63D H(CCO)NH1 mM U-13C-15N Yih190% H2O/10% D2O30 mM7.21 atm298Bruker AVANCE 700
73D HCCH-TOCSY1 mM U-13C-15N Yih190% H2O/10% D2O30 mM7.21 atm298Bruker AVANCE 700
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAVANCE700
NMR Refinement
MethodDetailsSoftware
simulated annealingexplicit waterX-PLOR NIH
NMR Ensemble Information
Conformer Selection Criteriastructures with the lowest energy
Conformers Calculated Total Number40
Conformers Submitted Total Number10
Representative Model1 (closest to the average)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1structure calculationCNSBrunger A. T. et.al.
2refinementX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore
3chemical shift assignmentCARAKeller and Wuthrich
4peak pickingCANDIDHerrmann, Guntert and Wuthrich