6EIW

Sacbrood virus of honeybee empty particle


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg29.779
r_dihedral_angle_4_deg12.09
r_dihedral_angle_3_deg11.718
r_dihedral_angle_1_deg5.479
r_long_range_B_refined4.962
r_long_range_B_other4.962
r_mcangle_it2.701
r_mcangle_other2.7
r_scangle_other1.717
r_mcbond_it1.434
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg29.779
r_dihedral_angle_4_deg12.09
r_dihedral_angle_3_deg11.718
r_dihedral_angle_1_deg5.479
r_long_range_B_refined4.962
r_long_range_B_other4.962
r_mcangle_it2.701
r_mcangle_other2.7
r_scangle_other1.717
r_mcbond_it1.434
r_mcbond_other1.434
r_angle_refined_deg0.935
r_scbond_it0.836
r_scbond_other0.835
r_angle_other_deg0.606
r_chiral_restr0.038
r_bond_refined_d0.004
r_gen_planes_refined0.002
r_bond_other_d0.001
r_gen_planes_other0.001
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Sacbrood virus
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK II
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles10303
Reported Resolution (Å)3.87
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetR-factor
Overall B Value99.36
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)21
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)4000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification75000
Calibrated Magnification74325
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsPreliminar grid screening was performed manually on FEI Tecnai F20 (cryo stage).
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf
MODEL FITTINGCoot
FINAL EULER ASSIGNMENTRELION2
CLASSIFICATIONRELION2
RECONSTRUCTIONRELION2
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION31804Full virions were selected together with empty particles from the same set of micrographs. Subsequent 2D classification sorted the particles of two types. Full and empty particles were further reconstructed separately.