5NZV

The structure of the COPI coat linkage IV


ELECTRON MICROSCOPY
Sample
The structure of the COPI coat leaf
Sample Components
COPI coat complex
ADP-ribosylation factor 1
Specimen Preparation
Sample Aggregation State3D ARRAY
Vitrification InstrumentHOMEMADE PLUNGER
Cryogen NameETHANE
Sample Vitrification DetailsThe sample was applied onto glow-discharged (30 sec, 20 mA) C-flat (Protochips Inc.) multihole grids. The grids were blotted from the back side for 11 ...The sample was applied onto glow-discharged (30 sec, 20 mA) C-flat (Protochips Inc.) multihole grids. The grids were blotted from the back side for 11 seconds at room temperature in a chamber at 85% humidity and plunge-frozen into liquid ethane using a manual plunger.
3D Reconstruction
Reconstruction MethodSUBTOMOGRAM AVERAGING
Number of Particles1640
Reported Resolution (Å)17.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetCross-correlation coefficient
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å**2)2
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)2500
Maximum Defocus (nm)5000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsTomographic tilt series were acquired with the dose-symmetric tilt-scheme (Hagen et al., J Struct Biol. 2017)
EM Software
TaskSoftware PackageVersion
VOLUME SELECTIONAmira
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND4
MODEL FITTINGUCSF Chimera1.11
RECONSTRUCTIONTOM Toolbox
VOLUME SELECTIONTOM Toolbox
CTF CORRECTIONIMOD
RECONSTRUCTIONAV3
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLYCTF-determination for each individual tilt image was performed using CTFFIND4. Strip-based CTF-correction and tomogram reconstruction was performed in Imod.