SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
1IPAP400 uM [U-15N] S100B, 10 mM CaCl2, 25 mM NaCl, 10 mM [U-99% 2H] MES, pH 6.7, 10 mM DTT, .1 mM NaN390% H2O/10% D2O506.7ambient310
2HNCOCA400 uM [U-15N] S100B, 10 mM CaCl2, 25 mM NaCl, 10 mM [U-99% 2H] MES, pH 6.7, 10 mM DTT, .1 mM NaN390% H2O/10% D2O506.7ambient310
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerDMX600
2BrukerAVANCE800
NMR Refinement
MethodDetailsSoftware
simulated annealingX-PLOR NIH
NMR Ensemble Information
Conformer Selection Criteriastructures with the lowest energy
Conformers Calculated Total Number200
Conformers Submitted Total Number20
Representative Model1 (closest to the average)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1processingX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore
2structure solutionX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore
3refinementX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore