 9Z0I | pdb_00009z0i

E2 Refolding into Soluble Protein after Dissociation from Viral Membrane and E1 during Sindbis Virus Fusion


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d5.9449
f_angle_d0.7618
f_chiral_restr0.0458
f_plane_restr0.0071
f_bond_d0.0032
Sample
Sindbis virus TE12 strain E2 homotrimer
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles339663
Reported Resolution (Å)3.87
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC3
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value
Fitting Procedure
DetailsThe model underwent cycles of refinement using a combination of Rosetta, Refmac_Servalcat, and Phenix. Final refinement and validation was performed w ...The model underwent cycles of refinement using a combination of Rosetta, Refmac_Servalcat, and Phenix. Final refinement and validation was performed with Phenix.
Data Acquisition
Detector TypeGATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å**2)1.0178
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONcryoSPARC
INITIAL EULER ASSIGNMENTcryoSPARC
CLASSIFICATIONcryoSPARC
RECONSTRUCTIONcryoSPARC
MODEL REFINEMENTPHENIX1.21.2_5419+SVN
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONcryosparc patch CTF correction617859181,852 particles were picked from non-tilt data; 218704 particles were picked from 30 degree tilt data; 46113 particles were picked from 60 degree data; 171186 particles were picked from 45 degree tilt data.