9YRG | pdb_00009yrg

Cryo-EM structure of human beta-cardiac myosin in the interacting-heads motif and S2-FH undocked state


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 8ACT 
experimental modelPDB 2FXM 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.904
f_angle_d0.54
f_chiral_restr0.036
f_plane_restr0.004
f_bond_d0.003
Sample
Human beta-cardiac myosin in the interacting-heads motif and S2-FH undocked state
Sample Components
Myosin-7
Myosin light chain 1/3 and Myosin regulatory light chain 11
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles69575
Reported Resolution (Å)3.2
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (8ACT)2 (2FXM)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)49.5
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC
PARTICLE SELECTIONTopaz
CTF CORRECTIONcryoSPARC
MODEL FITTINGUCSF ChimeraX
MODEL FITTINGMDFF
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTcryoSPARC
FINAL EULER ASSIGNMENTcryoSPARC
CLASSIFICATIONcryoSPARC
RECONSTRUCTIONcryoSPARC
MODEL REFINEMENTPHENIX1.20.1_4487
MODEL REFINEMENTPHENIX1.20.1_4487
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION