ELECTRON MICROSCOPY
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation |
| f_dihedral_angle_d | 9.121 |
| f_angle_d | 0.754 |
| f_chiral_restr | 0.044 |
| f_plane_restr | 0.008 |
| f_bond_d | 0.004 |
| Sample |
|---|
| Binary complex of human uPAR and Fab fragment of anti-uPAR antibody FL1 |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 184642 |
| Reported Resolution (Å) | 2.94 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | FLEXIBLE FIT | ||||
| Refinement Target | cross-correlation coefficient | ||||
| Overall B Value | 112 | ||||
| Fitting Procedure | |||||
| Details | An initial local fitting was performed with ISOLDE implemented in ChimeraX prior to real-space refinement in phenix. | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 10.7 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | TFS KRIOS |
| Minimum Defocus (nm) | 500 |
| Maximum Defocus (nm) | 2000 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
| Nominal Magnification | 105000 |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | cryoSPARC | 4.5.3 |
| IMAGE ACQUISITION | EPU | 3.9 |
| CTF CORRECTION | cryoSPARC | 4.5.3 |
| MODEL FITTING | ISOLDE | 1.10.1 |
| INITIAL EULER ASSIGNMENT | cryoSPARC | 4.5.3 |
| FINAL EULER ASSIGNMENT | cryoSPARC | 4.5.3 |
| CLASSIFICATION | cryoSPARC | 4.5.3 |
| RECONSTRUCTION | cryoSPARC | 4.5.3 |
| MODEL REFINEMENT | PHENIX | 1.21.2_5419: |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | CTF corrections were performed after 3D reconstruction to improve the final resolution | 7426690 | The 7426690 particles were picked by automated particle picking using blob picker. Several rounds of 2D classification were performed to discard particles of low quality, producing 184642 particles of good quality which were used for 3D reconstruction. | |














