9VIB | pdb_00009vib

cryo-EM structure of human haemoglobin in the R2 conformation


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 8WJ0 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg23.377
r_dihedral_angle_3_deg18.577
r_long_range_B_other16.822
r_long_range_B_refined16.821
r_scangle_other12.646
r_scbond_it8.171
r_scbond_other8.149
r_mcangle_it7.905
r_mcangle_other7.903
r_mcbond_it5.984
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg23.377
r_dihedral_angle_3_deg18.577
r_long_range_B_other16.822
r_long_range_B_refined16.821
r_scangle_other12.646
r_scbond_it8.171
r_scbond_other8.149
r_mcangle_it7.905
r_mcangle_other7.903
r_mcbond_it5.984
r_mcbond_other5.882
r_dihedral_angle_1_deg5.302
r_angle_refined_deg1.894
r_angle_other_deg0.65
r_chiral_restr0.097
r_bond_refined_d0.01
r_gen_planes_refined0.01
r_gen_planes_other0.008
r_bond_other_d
r_dihedral_angle_4_deg
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
human haemoglobin in carboxy form
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles148562
Reported Resolution (Å)2.26
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1 (8WJ0)
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)58.4
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)400
Maximum Defocus (nm)1200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.6.2
MODEL REFINEMENTREFMAC5.8.0419
CTF CORRECTIONcryoSPARC4.6.2
INITIAL EULER ASSIGNMENTcryoSPARC4.6.2
FINAL EULER ASSIGNMENTcryoSPARC4.6.2
RECONSTRUCTIONcryoSPARC4.6.2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION