9Q03 | pdb_00009q03

Cryo-EM structure of ternary complex BCL6-CRBN-DDB1 with BCL6-760 (LDD, local refined)


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB PDB_00009DQD 
experimental modelPDB PDB_00005X9O 
Sample
ternary complex of BCL6-CRBN-DDB1 with an LDD BCL6-760
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles112568
Reported Resolution (Å)3.15
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (pdb_00009dqd, pdb_00005x9o)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeTFS FALCON 4i (4k x 4k)
Electron Dose (electrons/Å**2)35.18
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1200
Maximum Defocus (nm)1800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC
PARTICLE SELECTIONTopaz
IMAGE ACQUISITIONEPU
CTF CORRECTIONcryoSPARC
MODEL FITTINGCoot
CLASSIFICATIONcryoSPARC
RECONSTRUCTIONcryoSPARC
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION15859703