☰ Navigation Tabs
ARP of SWI/SNF of PIC-Med-SWI/SNF
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 7C4J experimental model PDB 7EGP
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 6.463 f_angle_d 1.705 f_chiral_restr 0.098 f_bond_d 0.016 f_plane_restr 0.01
Sample ARP of SWI/SNF of PIC-Med-SWI/SNF
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 144924 Reported Resolution (Å) 4 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 (7c4j, 7egp) Refinement Space Refinement Protocol RIGID BODY FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 40.8
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 64000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION 5 MODEL REFINEMENT PHENIX 1.20.1_4487 IMAGE ACQUISITION SerialEM RECONSTRUCTION cryoSPARC
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION