9OSW | pdb_00009osw

Tetrameric POLQ Helicase-like Domain Bound to Cmpd 19, a Small-Molecule ATPase Inhibitor and Drug Candidate Analog


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 5AGA 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d5.961
f_angle_d0.819
f_chiral_restr0.038
f_bond_d0.009
f_plane_restr0.005
Sample
Polymerase theta N-terminal domain in complex with ATPase inhibitor compound
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details3 microL drop of sample suspension is applied to an EM grid that has been plasma-cleaned using a Gatan Solarus. After blotting the sample away with fi ...3 microL drop of sample suspension is applied to an EM grid that has been plasma-cleaned using a Gatan Solarus. After blotting the sample away with filter paper, grids are plunge-frozen in liquid ethane. Grids are stored under liquid nitrogen until transferred to the transmission electron microscope for imaging.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles674000
Reported Resolution (Å)2.67
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (5AGA)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetCC_mask: 0.8076
Overall B Value76.4
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1200
Maximum Defocus (nm)1800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC3.1
IMAGE ACQUISITIONLeginon
MODEL FITTINGCoot
MODEL REFINEMENTPHENIX1.19.2_4158
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION~14.5M particles were initially selected from 14,375 manually curated micrographs using cryoSPARC 3.1 live. All subsequent data processing was carried out in cryoSPARC 3.1.These particles were subjected to 3 rounds of 2D classification. A subset of particles from the final round of 2D classification were used to train the Deep Learning particle picker Topaz (as implemented in cryoSPARC 3.1). The Topaz trained model was used to re-extract particles from the 14,375 micrographs, yielding a new particle set comprising ~7M particles.