9I3O | pdb_00009i3o

Csu pilus rod type 2 stack


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7ZL4 
Sample
Csu pilus rod type 2 stack
Specimen Preparation
Sample Aggregation State2D ARRAY
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles687088
Reported Resolution (Å)4.7
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsLocal Refinement allowed generating a single map without individual particles flipping and settling into pseudosymmetric orientations.
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7ZL4)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value330.69
Fitting Procedure
DetailsUCSF Chimera was used to first fit the subunits into the single native pilus rod map (PDB Accession ID: 9I37) and average their relative angles, and i ...UCSF Chimera was used to first fit the subunits into the single native pilus rod map (PDB Accession ID: 9I37) and average their relative angles, and it was also used to adjust pixel spacing of all maps to match model dimensions. Coot was used to adjust side chain and loop positions. A pair of antiparallel pili with subunit angles adjusted to 3-turns-per-7-subunits symmetry was overlapped with a 2D class to adjust the binding junction angle. Finally, Phenix was used to fit the type 2 stack model into the map.
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)59.848
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)400
Maximum Defocus (nm)1600
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARCv4.5.3
IMAGE ACQUISITIONEPUv3.60
CTF CORRECTIONcryoSPARCv4.5.3
MODEL FITTINGUCSF Chimera1.15
MODEL FITTINGCoot0.8.9.2 EL
MODEL REFINEMENTPHENIX1.20.1_4487:
INITIAL EULER ASSIGNMENTcryoSPARCv4.5.3
FINAL EULER ASSIGNMENTcryoSPARCv4.5.3
CLASSIFICATIONcryoSPARCv4.5.3
RECONSTRUCTIONcryoSPARCv4.5.3
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION30605819Two different types of Csu pilus stack architectures were solved from the same particle set. Particle picking failed to distinguish between the two, so the initial number of particles is the same for both stack architectures.