9GHD | pdb_00009ghd

Escherichia coli 70S ribosome in complex with Staphylococcus aureus FusB-EF-G (FusB-EF-G-70S*)


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 8P2H 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_3_deg10.72
r_dihedral_angle_6_deg6.896
r_lrange_it5.05
r_lrange_other5.05
r_dihedral_angle_1_deg4.595
r_dihedral_angle_2_deg4.414
r_mcangle_it2.579
r_mcangle_other2.579
r_scangle_it2.505
r_scangle_other2.505
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_3_deg10.72
r_dihedral_angle_6_deg6.896
r_lrange_it5.05
r_lrange_other5.05
r_dihedral_angle_1_deg4.595
r_dihedral_angle_2_deg4.414
r_mcangle_it2.579
r_mcangle_other2.579
r_scangle_it2.505
r_scangle_other2.505
r_scbond_it1.402
r_scbond_other1.402
r_mcbond_it1.389
r_mcbond_other1.389
r_angle_refined_deg0.686
r_dihedral_angle_other_2_deg0.678
r_angle_other_deg0.268
r_nbtor_refined0.22
r_symmetry_nbd_other0.194
r_nbd_refined0.141
r_xyhbond_nbd_refined0.124
r_symmetry_nbtor_other0.072
r_symmetry_xyhbond_nbd_other0.031
r_chiral_restr0.028
r_bond_refined_d0.003
r_gen_planes_refined0.003
r_gen_planes_other0.001
r_bond_other_d
Sample
Staphylococcus aureus EF-G on 70S ribosomes
Sample Components
Staphylococcus aureus FusB-EF-G
mRNA
70S ribosome
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles30847
Reported Resolution (Å)2.41
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (8P2H, 9GHE)
Refinement SpaceREAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)45.47
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)700
Maximum Defocus (nm)1000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.4.1
IMAGE ACQUISITIONEPU
CTF CORRECTIONcryoSPARC4.4.1
MODEL FITTINGCoot0.9.8.92
INITIAL EULER ASSIGNMENTcryoSPARC4.4.1
FINAL EULER ASSIGNMENTcryoSPARC4.4.1
CLASSIFICATIONcryoSPARC4.4.1
RECONSTRUCTIONcryoSPARC4.4.1
MODEL REFINEMENTServalcat
MODEL REFINEMENTCoot0.9.8.92
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION3613403