Lymphostatin, conformation 2 (composite structure)
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 3.85 f_angle_d 0.648 f_chiral_restr 0.041 f_bond_d 0.005 f_plane_restr 0.005
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 182000 Reported Resolution (Å) 2.8 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details from the model of conformation 1 residues from G2434 to the end were first rigidly fitted into the map. Then further refinement followed.
Data Acquisition Detector Type FEI FALCON IV (4k x 4k) Electron Dose (electrons/Å**2) 70
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 500 Maximum Defocus (nm) 1400 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 130000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION cryoSPARC 4.4 IMAGE ACQUISITION EPU 4.0 CTF CORRECTION cryoSPARC 4.4 MODEL FITTING Coot 0.9.8.7 INITIAL EULER ASSIGNMENT cryoSPARC FINAL EULER ASSIGNMENT RELION 5.0 CLASSIFICATION RELION 5.0 RECONSTRUCTION RELION 5.0 MODEL REFINEMENT PHENIX 1.20.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 13373262