☰ Navigation Tabs
Cryo-EM structure of the ABC transporter PCAT1 bound with ATP and Substrate
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 4.4968 f_angle_d 0.5762 f_chiral_restr 0.0417 f_plane_restr 0.0042 f_bond_d 0.0035
Specimen Preparation Sample Aggregation State PARTICLE
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 108213 Reported Resolution (Å) 3.37 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C2
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 1.24872
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION cryoSPARC 4.2.1 CTF CORRECTION cryoSPARC 4.2.1 MODEL REFINEMENT PHENIX 1.20.1-4487 CLASSIFICATION cryoSPARC 4.2.1 RECONSTRUCTION cryoSPARC 4.2.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE 1303543