☰ Navigation Tabs
Cryo-EM structure of the FIGNL1 AAA hexamer bound to RAD51
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details in silico model AlphaFold
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 10.862 f_angle_d 0.55 f_chiral_restr 0.04 f_plane_restr 0.003 f_bond_d 0.002
Sample FIGNL1 hexamer bound to the N-terminus of RAD51
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 57484 Reported Resolution (Å) 3.2 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol OTHER Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 700 Maximum Defocus (nm) 2100 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 81000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION cryoSPARC 4.1.2 PARTICLE SELECTION RELION 4.0 IMAGE ACQUISITION EPU CTF CORRECTION CTFFIND 4.1 MODEL FITTING PHENIX MODEL FITTING Coot INITIAL EULER ASSIGNMENT RELION 4.0 FINAL EULER ASSIGNMENT RELION 4.0 CLASSIFICATION RELION 4.0 RECONSTRUCTION RELION 4.0 MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 1800000