☰ Navigation Tabs
Monomeric E6AP-E6-p53 ternary complex
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 11.49 f_angle_d 0.978 f_chiral_restr 0.068 f_plane_restr 0.016 f_bond_d 0.008
Sample Monomeric E6AP-E6-p53 ternary complex
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 297000 Reported Resolution (Å) 3.67 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol AB INITIO MODEL Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type FEI FALCON IV (4k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS GLACIOS Minimum Defocus (nm) 200 Maximum Defocus (nm) 2000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 120000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION cryoSPARC v.3 IMAGE ACQUISITION EPU 3.0 MODEL FITTING cryoSPARC v.3 RECONSTRUCTION cryoSPARC v.4 MODEL REFINEMENT cryoSPARC v.3 or v.4 MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 16800000 Blob picker