8CKV

HIV-1 mature capsid hexamer from CA-IP6 CLPs


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d12.358
f_angle_d0.834
f_chiral_restr0.05
f_plane_restr0.008
f_bond_d0.004
Sample
HIV-1 Mature Capsid
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles4742639
Reported Resolution (Å)2.89
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC6
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetCross-correlation
Overall B Value
Fitting Procedure
DetailsInitial model:4XFX
Data Acquisition
Detector TypeFEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å**2)40
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)600
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcrYOLO1.82
IMAGE ACQUISITIONEPU
CTF CORRECTIONcryoSPARC3.3.2
MODEL FITTINGUCSF Chimera
INITIAL EULER ASSIGNMENTcryoSPARC3.3.2
FINAL EULER ASSIGNMENTcryoSPARC3.3.2
CLASSIFICATIONcryoSPARC3.3.2
RECONSTRUCTIONcryoSPARC3.3.2
MODEL REFINEMENTISOLDE
MODEL REFINEMENTCoot
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION8718298