CHMP2A-CHMP3 heterodimer (410 Angstrom diameter)
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 6TZ4
Sample Membrane-bound CHMP2A-CHMP3 filament (410 Angstrom Diameter) cryo-EM map
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 11396 Reported Resolution (Å) 3.6 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 1.44 Angular Rotation 57.049
Map-Model Fitting and Refinement Id 1 (6TZ4) Refinement Space REAL Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 24
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 500 Maximum Defocus (nm) 1500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version IMAGE ACQUISITION EPU CTF CORRECTION CTFFIND 4 MODEL FITTING UCSF Chimera MODEL REFINEMENT Coot MODEL REFINEMENT PHENIX CLASSIFICATION RELION 3 RECONSTRUCTION RELION 3
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 89122