7OZL | pdb_00007ozl

CryoEM structure of human enterovirus 70 in complex with WIN51711


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined50.224
r_long_range_B_other50.22
r_scangle_other43.38
r_scbond_it37.336
r_scbond_other37.331
r_mcangle_it34.295
r_mcangle_other34.293
r_dihedral_angle_2_deg34.068
r_mcbond_other29.742
r_mcbond_it29.737
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined50.224
r_long_range_B_other50.22
r_scangle_other43.38
r_scbond_it37.336
r_scbond_other37.331
r_mcangle_it34.295
r_mcangle_other34.293
r_dihedral_angle_2_deg34.068
r_mcbond_other29.742
r_mcbond_it29.737
r_dihedral_angle_4_deg16.541
r_dihedral_angle_3_deg13.371
r_dihedral_angle_1_deg5.1
r_angle_other_deg2.243
r_angle_refined_deg1.622
r_chiral_restr0.09
r_bond_other_d0.035
r_gen_planes_other0.017
r_bond_refined_d0.014
r_gen_planes_refined0.008
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Human enterovirus 70 (strain J670/71)
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles17054
Reported Resolution (Å)2.74
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value42
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)48
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification75000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU1.8
CTF CORRECTIONGctf
CTF CORRECTIONRELION3.1
MODEL FITTINGUCSF Chimera
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
CLASSIFICATIONRELION3.1
RECONSTRUCTIONRELION3.1
MODEL REFINEMENTPHENIX
MODEL REFINEMENTREFMAC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION28058autopicking