☰ Navigation Tabs
N-terminal C2H2 Zn-finger domain of Clamp
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 2 2D 1H-15N HSQC 0.3 mM [U-99% 13C; U-99% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 95% H2O/5% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE 600 4 3D 1H-15N NOESY 0.3 mM [U-95% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 95% H2O/5% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE III 700 5 3D 1H-13C NOESY 0.3 mM [U-99% 13C; U-99% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 100% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE III 700 13 3D HNCO 0.3 mM [U-99% 13C; U-99% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 95% H2O/5% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE III 700 12 3D HN(CA)CO 0.3 mM [U-99% 13C; U-99% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 95% H2O/5% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE III 700 11 3D HNCACB 0.3 mM [U-99% 13C; U-99% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 95% H2O/5% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE III 700 10 3D CBCA(CO)NH 0.3 mM [U-99% 13C; U-99% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 95% H2O/5% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE III 700 9 3D 1H-15N TOCSY 0.3 mM [U-99% 13C; U-99% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 95% H2O/5% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE III 700 7 3D HCCH-TOCSY 0.3 mM [U-99% 13C; U-99% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 100% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE III 700 8 2D 15N HSQC-NOESY 0.3 mM [U-95% 15N] Clamp[86...153], 20 mM Na2HPO4/HaH2PO4, 50 mM NaCl, 1 mM DTT 100% D2O 70 mM 6.0 1 atm 298 Bruker AVANCE 600
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AVANCE III 700 2 Bruker AVANCE 600
NMR Refinement Method Details Software simulated annealing CNS
NMR Ensemble Information Conformer Selection Criteria structures with the lowest energy Conformers Calculated Total Number 100 Conformers Submitted Total Number 20 Representative Model 1 (closest to the average)
Computation: NMR Software # Classification Version Software Name Author 1 refinement CNS Brunger, Adams, Clore, Gros, Nilges and Read 2 collection TopSpin v3.1 Bruker Biospin 3 processing NMRPipe Delaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax 4 peak picking NMRFAM-SPARKY Woonghee Lee 5 data analysis NMRFAM-SPARKY Woonghee Lee 6 data analysis TALOS+ Yang Shen, Frank Delaglio, Gabriel Cornilescu, and Ad Bax