SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
12D 1H-1H TOCSY2 mM LyeTx I95% H2O/5% D2O20 mM71 atm293Bruker AVANCE DRX 600
22D 1H-1H NOESY2 mM LyeTx I95% H2O/5% D2O20 mM71 atm293Bruker AVANCE DRX 600
32D 1H-13C HSQC2 mM LyeTx I95% H2O/5% D2O20 mM71 atm293Bruker AVANCE DRX 600
42D 1H-15N HSQC2 mM LyeTx I95% H2O/5% D2O20 mM71 atm293Bruker AVANCE DRX 600
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAVANCE DRX600
NMR Refinement
MethodDetailsSoftware
simulated annealingX-PLOR NIH
NMR Ensemble Information
Conformer Selection Criteriastructures with the lowest energy
Conformers Calculated Total Number200
Conformers Submitted Total Number20
Representative Model1 (closest to the average)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1refinementX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore
2processingNMRDrawDelaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax
3chemical shift assignmentNMRViewJohnson, One Moon Scientific
4data analysisPROCHECK / PROCHECK-NMRLaskowski, MacArthur, Smith, Jones, Hutchinson, Morris, Moss and Thornton
5data analysisNMRPipeDelaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax
6data analysisQUEENNabuurs, Spronk, Krieger, Maassen, Vriend and Vuister