☰ Navigation Tabs
Cryo-EM structure of human ATG9A in amphipols
Sample Human ATG9A in amphipols A8-35
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument HOMEMADE PLUNGER Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 21710 Reported Resolution (Å) 3.4 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C3
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 66
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TALOS ARCTICA Minimum Defocus (nm) 500 Maximum Defocus (nm) 1800 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 73000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION 3.0 IMAGE ACQUISITION Leginon CTF CORRECTION Gctf INITIAL EULER ASSIGNMENT RELION FINAL EULER ASSIGNMENT RELION CLASSIFICATION RELION RECONSTRUCTION RELION