7F47

Cryo-EM structure of Rhizobium etli MprF


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it41.36
r_lrange_other41.359
r_dihedral_angle_2_deg29.554
r_scangle_it22.446
r_scangle_other22.444
r_dihedral_angle_4_deg20.545
r_mcangle_it20.02
r_mcangle_other20.017
r_dihedral_angle_3_deg19.09
r_scbond_it14.212
RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it41.36
r_lrange_other41.359
r_dihedral_angle_2_deg29.554
r_scangle_it22.446
r_scangle_other22.444
r_dihedral_angle_4_deg20.545
r_mcangle_it20.02
r_mcangle_other20.017
r_dihedral_angle_3_deg19.09
r_scbond_it14.212
r_scbond_other14.21
r_mcbond_other13.36
r_mcbond_it13.358
r_dihedral_angle_1_deg5.573
r_angle_refined_deg1.443
r_angle_other_deg1.342
r_ext_dist_refined_d0.266
r_nbd_refined0.215
r_symmetry_xyhbond_nbd_refined0.208
r_nbtor_refined0.169
r_symmetry_nbd_other0.168
r_nbd_other0.155
r_xyhbond_nbd_refined0.125
r_symmetry_xyhbond_nbd_other0.122
r_symmetry_nbtor_other0.078
r_symmetry_nbd_refined0.053
r_chiral_restr0.046
r_bond_refined_d0.007
r_gen_planes_refined0.007
r_gen_planes_other0.002
r_bond_other_d0.001
Sample
MprF
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Detailsa waiting time of 10 s and a blotting time of 4 s
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles307241
Reported Resolution (Å)2.99
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1 (5VRV)
Refinement SpaceRECIPROCAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)56
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsCDS mode
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.1
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
RECONSTRUCTIONRELION3.1
MODEL REFINEMENTREFMAC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION