☰ Navigation Tabs
RDC refined solution structure of the insecticidal toxin Ta1a
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 3D CT-HNCA 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 2 2D IPAP-HSQC 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 900 3 2D IPAP-HSQC 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 4 2D IPAP-HSQC 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 5 3D HNCO 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 6 3D HNCO 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 7 3D HNCO 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 8 3D CT-HN(CO)CA 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 9 3D CT-HN(CO)CA 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 10 3D CT-HN(CO)CA 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 11 2D 1H-15N TROSY 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 12 2D 1H-15N TROSY 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 13 2D 1H-15N TROSY 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 14 3D CT-HN(COCA)CB 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 700 15 3D CT-HN(COCA)CB 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 600 16 3D HA[HB,HN](CACO)NH 0.5 mM 13C/15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 700 17 3D HNHB 0.5 mM 15N U1-agatoxin-Ta1a 95% H2O/5% D2O 0 mM 6.2 1 bar 298 Bruker AVANCE III 900
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AVANCE III 600 2 Bruker AVANCE III 900 3 Bruker AVANCE III 700
NMR Refinement Method Details Software simulated annealing X-PLOR NIH
NMR Ensemble Information Conformer Selection Criteria structures with the lowest energy Conformers Calculated Total Number 50 Conformers Submitted Total Number 20 Representative Model 1 (medoid)
Computation: NMR Software # Classification Version Software Name Author 1 structure calculation X-PLOR NIH Schwieters, Kuszewski, Tjandra and Clore 3 processing NMRPipe Delaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax 4 data analysis CcpNmr Analysis CCPN 5 data analysis Sparky Goddard