6QKC

GluA1/2 In complex with auxiliary subunit gamma-8


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg31.225
r_dihedral_angle_3_deg17.994
r_long_range_B_refined11.513
r_long_range_B_other11.513
r_dihedral_angle_4_deg10.658
r_mcangle_other7.876
r_mcangle_it7.875
r_scangle_other6.665
r_dihedral_angle_1_deg4.708
r_mcbond_other4.296
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg31.225
r_dihedral_angle_3_deg17.994
r_long_range_B_refined11.513
r_long_range_B_other11.513
r_dihedral_angle_4_deg10.658
r_mcangle_other7.876
r_mcangle_it7.875
r_scangle_other6.665
r_dihedral_angle_1_deg4.708
r_mcbond_other4.296
r_mcbond_it4.294
r_scbond_it3.59
r_scbond_other3.589
r_angle_other_deg2.454
r_angle_refined_deg1.345
r_chiral_restr0.127
r_bond_other_d0.037
r_bond_refined_d0.013
r_gen_planes_other0.003
r_gen_planes_refined0.002
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
GluA1/A2 bound to gamma-8
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details3uL on grid, 60 sec incubation and 4sec blotting time
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles114730
Reported Resolution (Å)4.4
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1 (5WEO, 3UA8, 5KK2)
Refinement SpaceRECIPROCAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)32
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)-200
Maximum Defocus (nm)-900
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf1.06
MODEL FITTINGUCSF Chimera1.11.2
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTRELION3.0
CLASSIFICATIONRELION3.0
RECONSTRUCTIONRELION3.0
MODEL REFINEMENTREFMAC5.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION