6PZZ

CryoEM derived model of NA-80 Fab in complex with N9 Shanghai2


ELECTRON MICROSCOPY
Sample
NA-80 Fab in complex with N9 Shanghai2
Sample Components
N9 Shanghai2
NA-80 Fab
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles11240
Reported Resolution (Å)3.6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC4
Map-Model Fitting and Refinement
Id1 (5L14)
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification29000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONLeginon
CTF CORRECTIONGctf
MODEL FITTINGUCSF Chimera
INITIAL EULER ASSIGNMENTcryoSPARC1
FINAL EULER ASSIGNMENTcryoSPARC1
CLASSIFICATIONcryoSPARC1
RECONSTRUCTIONcryoSPARC1
MODEL REFINEMENTCoot
MODEL REFINEMENTRosetta3.10
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION