6ON2

Lon Protease from Yersinia pestis with Y2853 substrate


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d6.144
f_angle_d0.92
f_chiral_restr0.059
f_plane_restr0.008
f_bond_d0.007
Sample
Lon protease bound to Y2853 substrate
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentHOMEMADE PLUNGER
Cryogen NameETHANE
Sample Vitrification Details4 uL of sample was applied per grid and manually blotted for 4 seconds followed by immediately plunge-freezing in liquid ethane cooled by liquid nitro ...4 uL of sample was applied per grid and manually blotted for 4 seconds followed by immediately plunge-freezing in liquid ethane cooled by liquid nitrogen.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles118143
Reported Resolution (Å)3
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsFocused classification of final reconstruction was performed on E and F "step" subunits, resulting in a reconstruction with an overall resolution of 3 ...Focused classification of final reconstruction was performed on E and F "step" subunits, resulting in a reconstruction with an overall resolution of 3.5 A by FSC 0.143. The two maps were stitched together using vop max in UCSF Chimera. All three maps (two original and final composite) are deposited in this entry.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolAB INITIO MODEL
Refinement TargetCorrelation coefficient
Overall B Value52
Fitting Procedure
DetailsInitial homology model was built using SWISS-MODEL and initial rigid body docking was done using UCSF Chimera
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)52
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)800
Maximum Defocus (nm)1200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification36000
Calibrated Magnification43478
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging DetailsComa-free alignment procedure from Herzik & Wu, Nature Methods (2017). Preliminary grid screening was performed manually prior to data collection.
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONFindEM1
IMAGE ACQUISITIONLeginon3.0
CTF CORRECTIONRELION2.0b
MODEL FITTINGCoot0.8.8
INITIAL EULER ASSIGNMENTRELION2.0b
FINAL EULER ASSIGNMENTRELION2.0b
CLASSIFICATIONRELION2.0b
RECONSTRUCTIONRELION2.0b
MODEL REFINEMENTPHENIX1.11.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLYCTF correction in RELION1176206template-based cross correlation with FindEM