5ZAL

Cryo-EM structure of human Dicer and its complexes with a pre-miRNA substrate


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d9.66
f_angle_d1.411
f_chiral_restr0.068
f_plane_restr0.01
f_bond_d0.008
Sample
Dicer and trbp
Sample Components
Human Dicer-TRBP with Pre-let-7 complex Class I
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles130000
Reported Resolution (Å)4.7
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (5ZAK)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetCC
Overall B Value100
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)2500
Maximum Defocus (nm)3500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS0.01
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification89000
Calibrated Magnification36496
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Detailsno
EM Software
TaskSoftware PackageVersion
CTF CORRECTIONRELION2.1
MODEL FITTINGUCSF Chimera1.10
MODEL REFINEMENTPHENIX1.11
INITIAL EULER ASSIGNMENTRELION2.1
FINAL EULER ASSIGNMENTRELION2.1
CLASSIFICATIONRELION2.1
RECONSTRUCTIONRELION2.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION