☰ Navigation Tabs
Structure of PsDef1 defensin from Pinus sylvestris
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 2D DQF-COSY 0.4 mM PsDef1, 10 mM sodium acetate 90% H2O/10% D2O 0 4.5 ambient atm 306 Bruker AVANCE III 600 2 2D 1H-1H TOCSY 0.4 mM PsDef1, 10 mM sodium acetate 90% H2O/10% D2O 0 4.5 ambient atm 306 Bruker AVANCE III 600 3 2D 1H-1H NOESY 0.4 mM PsDef1, 10 mM sodium acetate 90% H2O/10% D2O 0 4.5 ambient atm 306 Bruker AVANCE III 600 4 2D 1H-1H TOCSY 0.4 mM PsDef1, 10 mM sodium acetate 90% H2O/10% D2O 0 4.5 ambient atm 306 Bruker AVANCE III 700 5 2D 1H-1H NOESY 0.4 mM PsDef1, 10 mM sodium acetate 90% H2O/10% D2O 0 4.5 ambient atm 306 Bruker AVANCE III 700 6 2D 1H-13C HSQC 0.4 mM PsDef1, 10 mM sodium acetate 90% H2O/10% D2O 0 4.5 ambient atm 306 Bruker AVANCE III 700 7 2D 1H-13C HMBC 0.4 mM PsDef1, 10 mM sodium acetate 90% H2O/10% D2O 0 4.5 ambient atm 306 Bruker AVANCE III 700 8 2D 1H-13C TOCSY-HSQC 0.4 mM PsDef1, 10 mM sodium acetate 90% H2O/10% D2O 0 4.5 ambient atm 306 Bruker AVANCE III 700 9 2D 1H-15N HSQC 0.7 mM [U-15N] PsDef1, 10 mM sodium acetate 90% H2O/10% D2O 0 4.5 ambient atm 306 Bruker AVANCE III 700
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AVANCE III 700 2 Bruker AVANCE III 600 3 Bruker AVANCE III 500
NMR Ensemble Information Conformer Selection Criteria Conformers Calculated Total Number Conformers Submitted Total Number 15
Computation: NMR Software # Classification Version Software Name Author 1 refinement CNS Brunger A. T. et.al.