5MDX

Cryo-EM structure of the PSII supercomplex from Arabidopsis thaliana


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d11.328
f_angle_d1.941
f_chiral_restr0.055
f_plane_restr0.017
f_bond_d0.006
Sample
C2S2M2 supercomplex of Photosystem II
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles23434
Reported Resolution (Å)5.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetCross-correlation coefficient
Overall B Value
Fitting Procedure
DetailsInitial fitting of the subunits in the cryo-EM map was performed by rigid body real space refinement, using as templates the high resolution crystal ...Initial fitting of the subunits in the cryo-EM map was performed by rigid body real space refinement, using as templates the high resolution crystal structures of Thermosynechococcus vulcanus PSII (PDB code 3WU2), pea LHC-II (PDB code 2BHW for the S- and M-trimers, and spinach CP29 (PDB code 3PL9) for CP29, CP26 and CP24. Local fitting and adjustment of the subunits in the cryo-EM maps was performed using manual rebuilding and restrained real space refinement as explained in the primary reference. Due to large differences in local resolution of the cryo-EM map, refinement of the PSII core, the S-trimer with CP26/CP29 and the M-trimer with CP24 was performed separately in excised parts of the cryo-EM map. The core was refined at 4.5 angstrom, the S-trimer+CP26+CP29 at 5.5 angstrom and the M-trimer+CP24 at 6.5 angstrom. Core: chains A,B,C,D,E,F,H,I,J,K,L,M,O,T,W,X,Z and a,b,c,d,e,f,h,i,j,k,l,m,o,t,w,x,z. S-trimer+CP26+CP29: chains G,N,Y,S,R and g,n,y,s,r. M-trimer+CP24: chains 1,2,3,4 and 5,6,7,8.
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)38
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1200
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
CTF CORRECTIONRELION1.3
MODEL FITTINGCoot0.8.6
INITIAL EULER ASSIGNMENTRELION1.3
FINAL EULER ASSIGNMENTRELION1.3
CLASSIFICATIONRELION1.3
RECONSTRUCTIONRELION1.3
MODEL REFINEMENTPHENIXdev_2474
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION