Cryo-EM structure of the E. coli replicative DNA polymerase-clamp-exonuclase-theta complex bound to DNA in the editing mode
ELECTRON MICROSCOPY
| Sample |
|---|
| DNA polymerase III alpha, beta, epsilon, theta complex with mismatched DNA duplex |
| Sample Components |
| DNA polymerase III alpha, beta, epsilon, theta complex with mismatched DNA duplex |
| mismatched DNA duplex |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | Prior to sample preparation 0.1 volumes of 0.05% Tween 20 were added to the sample 3 microliters were pipetted onto the grid and blotted for 4 seconds ... |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 15616 |
| Reported Resolution (Å) | 6.7 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | |||||
| Refinement Protocol | OTHER | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | The cryo-EM structure of the PolIIIalpha-clamp-exonuclease complex in the polymerase mode (PDB code: 5FKW) was used as a starting model, and the NMR s ... | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 2 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 1800 |
| Maximum Defocus (nm) | 3500 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
| Nominal Magnification | 64000 |
| Calibrated Magnification | 79545 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | RELION | 2 |
| IMAGE ACQUISITION | DigitalMicrograph | 2.3 |
| IMAGE ACQUISITION | Titan User Interface | |
| CTF CORRECTION | Gctf | |
| MODEL FITTING | Coot | 0.8.2 |
| INITIAL EULER ASSIGNMENT | RELION | 2 |
| FINAL EULER ASSIGNMENT | RELION | 2 |
| CLASSIFICATION | RELION | 2 |
| RECONSTRUCTION | RELION | 2 |
| MODEL REFINEMENT | REFMAC | 5.8 |
| MODEL REFINEMENT | LIBG | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| NONE | 150000 | |||














