ELECTRON MICROSCOPY
| Sample |
|---|
| EPN-01* |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK II |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | 11 second blot, 0 mm offset |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 8573 |
| Reported Resolution (Å) | 5.7 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | I |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | |||||
| Refinement Protocol | RIGID BODY FIT | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 2 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TECNAI F20 |
| Minimum Defocus (nm) | |
| Maximum Defocus (nm) | |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | GATAN 626 SINGLE TILT LIQUID NITROGEN CRYO TRANSFER HOLDER |
| Nominal Magnification | |
| Calibrated Magnification | 41911 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 200 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | Scipion | |
| PARTICLE SELECTION | Xmipp | |
| IMAGE ACQUISITION | SerialEM | |
| CTF CORRECTION | CTFFIND | |
| CTF CORRECTION | Scipion | |
| MODEL FITTING | UCSF Chimera | |
| INITIAL EULER ASSIGNMENT | RELION | |
| INITIAL EULER ASSIGNMENT | Scipion | |
| FINAL EULER ASSIGNMENT | RELION | |
| FINAL EULER ASSIGNMENT | Scipion | |
| CLASSIFICATION | RELION | |
| CLASSIFICATION | Scipion | |
| RECONSTRUCTION | RELION | |
| RECONSTRUCTION | Scipion | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 9177 | |||














