5KC2

Negative stain structure of Vps15/Vps34 complex


ELECTRON MICROSCOPY
Sample
Vps15/34
Specimen Preparation
Sample Aggregation StatePARTICLE
Staining TypeNEGATIVE
Staining MaterialUranyl acetate
Staining Detailsdroplet technique
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles14172
Reported Resolution (Å)28
Resolution MethodFSC 0.5 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Data Acquisition
Detector TypeGATAN ULTRASCAN 4000 (4k x 4k)
Electron Dose (electrons/Å**2)20
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI POLARA 300
Minimum Defocus (nm)1000
Maximum Defocus (nm)1500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelOTHER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)120
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONEMAN2
CTF CORRECTIONEMAN2
INITIAL EULER ASSIGNMENTSPIDER
FINAL EULER ASSIGNMENTSPIDER
CLASSIFICATIONIMAGIC
RECONSTRUCTIONSPIDER
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLY14172