5GAM

Foot region of the yeast spliceosomal U4/U6.U5 tri-snRNP


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined41.905
r_long_range_B_other41.905
r_dihedral_angle_2_deg33.962
r_scangle_other32.512
r_mcangle_it31.175
r_mcangle_other31.174
r_mcbond_other20.725
r_mcbond_it20.724
r_scbond_it20.398
r_scbond_other20.397
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined41.905
r_long_range_B_other41.905
r_dihedral_angle_2_deg33.962
r_scangle_other32.512
r_mcangle_it31.175
r_mcangle_other31.174
r_mcbond_other20.725
r_mcbond_it20.724
r_scbond_it20.398
r_scbond_other20.397
r_dihedral_angle_3_deg17.525
r_dihedral_angle_4_deg12.922
r_dihedral_angle_1_deg12.837
r_angle_refined_deg1.388
r_angle_other_deg1.047
r_chiral_restr0.22
r_bond_refined_d0.007
r_gen_planes_refined0.007
r_bond_other_d0.002
r_gen_planes_other0.002
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Foot region of the yeast spliceosomal U4/U6.U5 tri-snRNP
Specimen Preparation
Sample Aggregation StatePARTICLE
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles140155
Reported Resolution (Å)3.7
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)38
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)3500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification81000
Calibrated Magnification35714
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION
IMAGE ACQUISITIONDigitalMicrograph
CTF CORRECTIONCTFFIND4
MODEL FITTINGCoot0.8.3
MODEL REFINEMENTREFMAC5.8
INITIAL EULER ASSIGNMENTRELION
FINAL EULER ASSIGNMENTRELION
CLASSIFICATIONRELION
RECONSTRUCTIONRELION
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLY473827