ELECTRON MICROSCOPY
| Sample |
|---|
| BOVINE MITOCHONDRIAL ATP SYNTHASE |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK III |
| Cryogen Name | ETHANE-PROPANE |
| Sample Vitrification Details | VITRIFICATION 1 -- CRYOGEN- ETHANE-PROPANE MIXTURE, HUMIDITY- 100, INSTRUMENT- FEI VITROBOT MARK III, METHOD- BLOT FOR 27 SECONDS BEFORE PLUNGING, |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 19250 |
| Reported Resolution (Å) | 7.2 |
| Resolution Method | |
| Other Details | THE A SUBUNIT WAS MODELLED USING EVOLUTIONARY CO-VARIANCE. THE N-TERMINAL TRANSMEMBRANE HELICES OF THE B SUBUNIT WERE MODELLED BASED ON TRANSMEMBRANE ... |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (2WSS, 2XND, 2CLY) | ||||
| Refinement Space | |||||
| Refinement Protocol | FLEXIBLE FIT | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | METHOD--FLEXIBLE FITTING | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 60.3 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | 2015-03-15 |
| Temperature (Kelvin) | 80 |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 1200 |
| Maximum Defocus (nm) | 4100 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | 18000 |
| Calibrated Magnification | 30487 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details | K2 SUMMIT DIRECT DETECTOR DEVICE (GATAN INC.) OPERATED IN SUPER-RESOLUTION MODE WITH A 1.64 ANGSTROM PHYSICAL PIXEL AND 0. 82 ANGSTROM SUPER- RESOLUTION PIXEL. WITH NO SPECIMEN PRESENT, THE RATE OF EXPOSURE OF THE DETECTOR WAS 8 ELECTRONS PER PIXEL PER SECOND. EXPOSURE- FRACTIONATED MOVIES OF 20.1 S WERE RECORDED AS STACKS OF 67 FRAMES, SO THAT SELECTED SPECIMEN AREAS WERE EXPOSED WITH A TOTAL OF 60.3 ELECTRONS PER SQUARE ANGSTROM. |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| MODEL FITTING | MDFF | |
| MODEL FITTING | UCSF Chimera | |
| RECONSTRUCTION | FREALIGN | |
| RECONSTRUCTION | RELION | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| EACH PARTICLE | ||||