☰ Navigation Tabs
INHIBITOR-FREE CATALYTIC FRAGMENT OF HUMAN FIBROBLAST COLLAGENASE, NMR, MINIMIZED AVERAGE STRUCTURE
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 NOESY 10 mM TRIS BASE, 100 mM NACL, 5 mM CACL2, 0.1 mM ZNCL2, 2mM NAN3, 10 mM DEUTERATED DTT, 90% H2O/10%D2O OR 100% D2O 6.5 1 atm 308 2 COSY 10 mM TRIS BASE, 100 mM NACL, 5 mM CACL2, 0.1 mM ZNCL2, 2mM NAN3, 10 mM DEUTERATED DTT, 90% H2O/10%D2O OR 100% D2O 6.5 1 atm 308 3 TOCSY 10 mM TRIS BASE, 100 mM NACL, 5 mM CACL2, 0.1 mM ZNCL2, 2mM NAN3, 10 mM DEUTERATED DTT, 90% H2O/10%D2O OR 100% D2O 6.5 1 atm 308 4 TRIPLE-RESONANCE 10 mM TRIS BASE, 100 mM NACL, 5 mM CACL2, 0.1 mM ZNCL2, 2mM NAN3, 10 mM DEUTERATED DTT, 90% H2O/10%D2O OR 100% D2O 6.5 1 atm 308 5 ETC. 10 mM TRIS BASE, 100 mM NACL, 5 mM CACL2, 0.1 mM ZNCL2, 2mM NAN3, 10 mM DEUTERATED DTT, 90% H2O/10%D2O OR 100% D2O 6.5 1 atm 308
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AMX2600 600
NMR Refinement Method Details Software HYBRID DISTANCE GEOMETRY-DYNAMICAL SIMULATED ANNEALING METHOD REFINEMENT DETAILS CAN BE FOUND IN THE JRNL CITATION ABOVE. X-PLOR
NMR Ensemble Information Conformer Selection Criteria LOWEST ENERGY, LOWEST VIOLATIONS, CONSISTENT FOLD Conformers Calculated Total Number 100 Conformers Submitted Total Number 1
Computation: NMR Software # Classification Version Software Name Author 1 refinement X-PLOR 3.84 BRUNGER 2 structure solution X-PLOR