ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelOther 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d15.661
f_angle_d0.5158
f_chiral_restr0.041
f_bond_d0.0039
f_plane_restr0.0038
Sample
ORC-Cdc6 complex of Yarrowia lipolytica bound to a 60bp DNA segment of a mutant of OriA-006 containing the CNNGGNR mutation
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification DetailsSample was applied to a non-glow discharged Quantifoil R 1.2/1.3 300 mesh copper grid (previously washed with ethyl acetate), incubated for 10 seconds ...Sample was applied to a non-glow discharged Quantifoil R 1.2/1.3 300 mesh copper grid (previously washed with ethyl acetate), incubated for 10 seconds at 25C and 95% humidity, blotted for 2.7 seconds, and plunged into liquid ethane using a Leica Automatic Plunge Freezer EM GP2.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles51222
Reported Resolution (Å)2.56
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsNon-uniform refinement was used for the final reconstruction.
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsThe YlODC60bpOriA-006-WT structure was docked into the map using ChimeraX and used as a starting point, with the DNA sequence altered at the mutated s ...The YlODC60bpOriA-006-WT structure was docked into the map using ChimeraX and used as a starting point, with the DNA sequence altered at the mutated sites and manual refinement in Coot used to refine the model.
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)54.8
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)600
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.7.1
MODEL REFINEMENTPHENIX2.0_5885
CTF CORRECTIONcryoSPARC4.7.1
INITIAL EULER ASSIGNMENTcryoSPARC4.7.1
FINAL EULER ASSIGNMENTcryoSPARC4.7.1
CLASSIFICATIONcryoSPARC4.7.1
RECONSTRUCTIONcryoSPARC4.7.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONPatch CTF correction was carried out in cryoSPARC using the default settings, and was optimized during the refinements/reconstruction of the map in cryoSPARC.27103988,428 movies were imported into cryoSPARC and underwent patch motion correction and patch CTF corrections to generate corrected micrographs. Template picking of micrographs commenced using representative 2D class averages of the particles used in the final YlODC60bpOri-A006-WT refinement, resulting in 4,708,382 particles being picked. Micrographs and respective particles were then analyzed using the Micrograph Junk Detector job, and after exposure and particle curation resulted in 2,710,398 particles from 7,330 micrographs. Particles were then extracted with a box size of 432 px and Fourier cropped to 128 px.