6P3E

Mobile loops and electrostatic interactions maintain the flexible lambda tail tube


ELECTRON MICROSCOPY
Sample
tail tube of the lambda phage
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK II
Cryogen NameETHANE-PROPANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles5543
Reported Resolution (Å)5.4
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC6
Axial Rise42.8
Angular Rotation17.5
Map-Model Fitting and Refinement
Id1 (2K4Q, 2L04)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value200
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)20
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI POLARA 300
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONEMAN2
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND
MODEL FITTINGUCSF Chimera
MODEL REFINEMENTPHENIX
MODEL REFINEMENTMDFF
INITIAL EULER ASSIGNMENTRELION2
FINAL EULER ASSIGNMENTRELION2
RECONSTRUCTIONRELION
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION7934