ELECTRON MICROSCOPY Experimental Data



EM Sample
Sample Vitrification Details --
Sample Aggregation State FILAMENT
Sample Reconstruction Method HELICAL
Name of Sample Ebola virus nucleoprotein bound to RNA
EM Data Acquisition
Date of Experiment --
Temperature (Kelvin) --
Microscope Model FEI TALOS ARCTICA
Detector Type GATAN K2 SUMMIT (4k x 4k)
Minimum Defocus (nm) --
Maximum Defocus (nm) --
Minimum Tilt Angle (degrees) --
Maximum Tilt Angle (degrees) --
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Electron Dose (electrons per Å**-2) 49.7
Illumination Mode FLOOD BEAM
Nominal Magnification --
Calibrated Magnification 47478
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 200
Imaging Details --
3D Reconstruction
Software Package(s) RELION
Reconstruction Method(s) --
EM Image Reconstruction Statistics
Number of Particles 24609
Other Details --
Effective Resolution 3.1
EM Map-Model Fitting and Refinement
Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Fitting Software
REAL -- -- -- -- --