X-RAY DIFFRACTION Experimental Data & Validation


X-ray Experimental Help

Crystallization

Crystalization Experiments
Method Vapor Diffusion Hanging Drop
pH 8
Temperature 298.0
Details 16% PEG4000, 100mM Tris-HCL, pH 8, VAPOR DIFFUSION, HANGING DROP, temperature 298K

Crystal Data

Unit Cell
Length (Å) Angle (°)
a = 154.52 α = 90
b = 97.18 β = 105.36
c = 67.1 γ = 90
Symmetry
Space Group C 1 2 1

Diffraction

Diffraction Experiment
ID # Data Collection Temperature
1 100
Diffraction Detector
Detector Diffraction Type Details Collection Date
CCD ADSC QUANTUM 315 -- --
Diffraction Radiation
Monochromator Protocol
-- SINGLE WAVELENGTH
Diffraction Detector Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ALS BEAMLINE 8.2.2 1 ALS 8.2.2

Data Collection

Overall
Resolution (High) Resolution (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.2 40 -- -- -- -- -- -- 48623 2.0 2.0 --

Refinement

Statistics
Structure Solution Method Refinement High Resolution Refinement Low Resolution Cut-off Sigma (I) Cut-off Sigma (F) Number of Reflections (All) Number of Reflections (Observed) Number of Reflections (R-Free) Percent Reflections (Observed) R-Factor (All) R-Factor (Observed) R-Work R-Free R-Free Selection Details
MOLECULAR REPLACEMENT 2.2 40.0 -- -- 48623 45497 2285 -- -- 0.22 0.21 0.255 RANDOM
Number of Non-Hydrogen Atoms Used in Refinement
Non-Hydrogen Atoms Numbers
Protein Atoms 6351
Nucleic Acid Atoms 0
Heterogen Atoms 184
Solvent Atoms 375

Software

Software
Software Name Purpose
HKL-2000 data collection
PHASES phasing
CNS refinement version: 1.1
HKL-2000 data reduction
HKL-2000 data scaling