ELECTRON MICROSCOPY Experimental Data



EM Sample
Sample Vitrification Details VITRIFICATION 1 -- CRYOGEN- ETHANE, INSTRUMENT- LEICA EM CPC, METHOD- BLOT FOR 2 SECONDS BEFORE PLUNGING,
Sample Aggregation State FILAMENT
Sample Reconstruction Method HELICAL
Name of Sample NATIVE INFLUENZA A VIRUS RIBONUCLEOPROTEIN (STRAIN A WSN 33, H1N1)
EM Data Acquisition
Date of Experiment 2011-01-01
Temperature (Kelvin) --
Microscope Model FEI TECNAI F20
Detector Type FEI EAGLE (4k x 4k)
Minimum Defocus (nm) 1500.0
Maximum Defocus (nm) 3500.0
Minimum Tilt Angle (degrees) --
Maximum Tilt Angle (degrees) --
Nominal CS 2.26
Imaging Mode BRIGHT FIELD
Electron Dose (electrons per Å**-2) --
Illumination Mode FLOOD BEAM
Nominal Magnification 65000
Calibrated Magnification --
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 200
Imaging Details --
3D Reconstruction
Software Package(s) IHRSR, SPIDER, Xmipp
Reconstruction Method(s) --
EM Image Reconstruction Statistics
Number of Particles 876
Other Details SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-2205.(DEPOSITION ID: 10953).
Effective Resolution 18.0
EM Map-Model Fitting and Refinement
Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Fitting Software
REAL RIGID BODY FIT VOLUMETRIC -- -- --