POP-OUT | CLOSE
 
X-RAY DIFFRACTION
Materials and Methods page
2PYR
  •   Crystallization Hide
    Crystallization Experiments
    pH 7
    Details pH 7.0
     
  •   Crystal Data Hide
    Unit Cell
    Length    (Å) Angle    (°)
    a = 66.9 α = 90
    b = 66.9 β = 90
    c = 40.8 γ = 120
     
    Space Group
    Space Group Name:    P 63
     
     
  •   Diffraction Hide
    Diffraction Experiment
    Diffrn ID 1
    Data Collection Temperature 287
     
    Diffraction Detector
    Detector CCD AREA DETECTOR
    Type THOMPSON
    Collection Date 1996-11
     
    Diffraction Radiation
     
    Diffraction Source
    Source SYNCHROTRON
    Type ESRF BEAMLINE ID09
    Wavelength 0.3
    Site ESRF
    Beamline ID09
     
     
  •   Refinement Data Hide
    Reflection Details
    Resolution(High) 1.5
    Resolution(Low) 20
    Number Reflections(Observed) 13027
    Percent Possible(Observed) 83.4
    R Merge I(Observed) 0.092
    Redundancy 14.0
     
    High Resolution Shell Details
    Resolution(High) 1.5
    Resolution(Low) 1.57
    Percent Possible(All) 44.8
    Redundancy 14.0
     
     
  •   Refinement Hide
    Refinement Statistics
    reflnsShellList 1.9
    Resolution(Low) 20.0
     
    Temperature Factor Modeling
    Data Not Available
     
    Number of Non-Hydrogen Atoms Used in Refinement
    Protein Atoms 976
    Nucleic Acid Atoms 0
    Heterogen Atoms 11
    Solvent Atoms 92
     
     
  •   Software and Computing Hide
    Computing
    Data Reduction (intensity integration) LAUEVIEW
    Data Reduction (data scaling) LAUEVIEW
    Structure Solution X-PLOR, XTALVIEW
    Structure Refinement X-PLOR
     
    Software
    refinement X-PLOR
    model building XTALVIEW
    model building X-PLOR