X-RAY DIFFRACTION Experimental Data & Validation


X-ray Experimental Help

Crystallization

Crystalization Experiments
Method Vapor Diffusion
Temperature 298.0
Details VAPOR DIFFUSION, temperature 298K

Crystal Data

Unit Cell
Length (Å) Angle (°)
a = 93.8 α = 90
b = 93.8 β = 90
c = 131.4 γ = 120
Symmetry
Space Group P 61 2 2

Diffraction

Diffraction Experiment
ID # Data Collection Temperature
1 293
Diffraction Detector
Detector Diffraction Type Details Collection Date
AREA DETECTOR UCSD MARK III -- --
Diffraction Radiation
Monochromator Protocol
-- SINGLE WAVELENGTH
Diffraction Detector Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU RU200 1.54 -- --

Data Collection

Overall
Resolution (High) Resolution (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.65 30.45 86.6 0.07 -- -- -- 33083 33083 0.0 0.0 --

Refinement

Statistics
Structure Solution Method Refinement High Resolution Refinement Low Resolution Cut-off Sigma (I) Cut-off Sigma (F) Number of Reflections (All) Number of Reflections (Observed) Number of Reflections (R-Free) Percent Reflections (Observed) R-Factor (All) R-Factor (Observed) R-Work R-Free R-Free Selection Details
MOLECULAR REPLACEMENT 1.7 20.0 -- 0.0 32986 32986 -- -- 0.155 0.155 -- -- --
RMS Deviations
Key Refinement Restraint Deviation
t_bond_d 0.019
t_angle_deg 2.8
Number of Non-Hydrogen Atoms Used in Refinement
Non-Hydrogen Atoms Numbers
Protein Atoms 2432
Nucleic Acid Atoms 0
Heterogen Atoms 34
Solvent Atoms 169

Software

Computing
Computing Package Purpose
SDMS Data Reduction (intensity integration)
SDMS Data Reduction (data scaling)
TNT Structure Solution
TNT Structure Refinement
Software
Software Name Purpose
TNT refinement
TNT model building
SDMS data reduction
SDMS data collection