X-RAY DIFFRACTION Experimental Data & Validation


X-ray Experimental Help

Crystallization

Crystalization Experiments
Method Vapor Diffusion Hanging Drop
Details VAPOR DIFFUSION, HANGING DROP

Crystal Data

Unit Cell
Length (Å) Angle (°)
a = 85.4 α = 90
b = 90.1 β = 90
c = 125.3 γ = 90
Symmetry
Space Group P 21 21 21

Diffraction

Diffraction Experiment
ID # Data Collection Temperature
1 100
Diffraction Detector
Detector Diffraction Type Details Collection Date
-- -- -- 2002-03-15
Diffraction Radiation
Monochromator Protocol
osmic mirrors SINGLE WAVELENGTH
Diffraction Detector Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU RU300 -- -- --

Data Collection

Overall
Resolution (High) Resolution (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.9 20 -- -- -- -- -- -- 76165 -- 0.0 --

Refinement

Statistics
Structure Solution Method Refinement High Resolution Refinement Low Resolution Cut-off Sigma (I) Cut-off Sigma (F) Number of Reflections (All) Number of Reflections (Observed) Number of Reflections (R-Free) Percent Reflections (Observed) R-Factor (All) R-Factor (Observed) R-Work R-Free R-Free Selection Details
MOLECULAR REPLACEMENT 1.9 50.0 0.0 0.0 76097 73057 3040 95.2 -- -- 0.242 0.283 random
Number of Non-Hydrogen Atoms Used in Refinement
Non-Hydrogen Atoms Numbers
Protein Atoms 6190
Nucleic Acid Atoms 0
Heterogen Atoms 2
Solvent Atoms 794

Software

Computing
Computing Package Purpose
R-AXIS Data Reduction (intensity integration)
R-AXIS Data Reduction (data scaling)
AMORE Structure Solution
CNS 1.0 Structure Refinement
Software
Software Name Purpose
CNS version: 1.0 refinement
AMoRE model building
R-AXIS data reduction
R-AXIS data collection