X-RAY DIFFRACTION Experimental Data & Validation


X-ray Experimental Help

Crystal Data

Unit Cell
Length (Å) Angle (°)
a = 129.22 α = 90
b = 60.45 β = 119.02
c = 56.77 γ = 90
Symmetry
Space Group C 1 2 1

Diffraction

Diffraction Detector
Detector Diffraction Type Details Collection Date
AREA DETECTOR SIEMENS -- 1994-04-08
Diffraction Radiation
Monochromator Protocol
-- --
Diffraction Detector Source
Source Type Wavelength List Synchrotron Site Beamline
-- -- -- -- --

Data Collection

Overall
Resolution (High) Resolution (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
-- -- 82.8 0.082 -- -- 2.2 -- 21066 -- -- --

Refinement

Statistics
Structure Solution Method Refinement High Resolution Refinement Low Resolution Cut-off Sigma (I) Cut-off Sigma (F) Number of Reflections (All) Number of Reflections (Observed) Number of Reflections (R-Free) Percent Reflections (Observed) R-Factor (All) R-Factor (Observed) R-Work R-Free R-Free Selection Details
-- 2.0 7.0 -- 2.0 -- 16783 -- 66.1 -- 0.167 0.167 -- --
RMS Deviations
Key Refinement Restraint Deviation
x_bond_d 0.016
Coordinate Error
Parameter Value
Luzzati ESD (Observed) 0.25
Number of Non-Hydrogen Atoms Used in Refinement
Non-Hydrogen Atoms Numbers
Protein Atoms 2725
Nucleic Acid Atoms 0
Heterogen Atoms 0
Solvent Atoms 142

Software

Computing
Computing Package Purpose
XENGEN Data Reduction (intensity integration)
XENGEN Data Reduction (data scaling)
X-PLOR 3.1 Structure Solution
X-PLOR 3.1 Structure Refinement
Software
Software Name Purpose
X-PLOR version: 3.1 refinement
X-PLOR version: 3.1 model building
XENGEN data reduction
XENGEN data collection