X-RAY DIFFRACTION Experimental Data & Validation


X-ray Experimental Help

Crystallization

Crystalization Experiments
Method Vapor Diffusion Hanging Drop
pH 5.9
Temperature 293.0
Details PEG6000, pH 5.9, VAPOR DIFFUSION, HANGING DROP, temperature 293K

Crystal Data

Unit Cell
Length (Å) Angle (°)
a = 46.46 α = 90
b = 85.95 β = 90
c = 76.1 γ = 90
Symmetry
Space Group P 21 21 21

Diffraction

Diffraction Experiment
ID # Data Collection Temperature
1 293
Diffraction Detector
Detector Diffraction Type Details Collection Date
AREA DETECTOR SIEMENS HI-STAR -- 1996-09-12
Diffraction Radiation
Monochromator Protocol
Cu SINGLE WAVELENGTH
Diffraction Detector Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE MACSCIENCE 1.54 -- --

Data Collection

Overall
Resolution (High) Resolution (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.62 -- 89.0 0.058 -- -- -- 135942 35322 -- -- --

Refinement

Statistics
Structure Solution Method Refinement High Resolution Refinement Low Resolution Cut-off Sigma (I) Cut-off Sigma (F) Number of Reflections (All) Number of Reflections (Observed) Number of Reflections (R-Free) Percent Reflections (Observed) R-Factor (All) R-Factor (Observed) R-Work R-Free R-Free Selection Details
-- 1.65 10.0 -- 2.0 -- 31097 -- -- -- -- 0.173 0.242 RANDOM
RMS Deviations
Key Refinement Restraint Deviation
x_improper_angle_d 1.06
x_bond_d 0.012
x_angle_deg 2.67
x_dihedral_angle_d 24.2
Number of Non-Hydrogen Atoms Used in Refinement
Non-Hydrogen Atoms Numbers
Protein Atoms 2566
Nucleic Acid Atoms 0
Heterogen Atoms 5
Solvent Atoms 256

Software

Software
Software Name Purpose
SAINT data scaling
SAINT data reduction
X-PLOR refinement version: 3.1