SOLUTION NMR Experimental Data


Experimental Details
Sample Conditions
Sample ContentsAcetate buffer
Solvent90% H2O, 10% D2O
Ionic Strength0.02
pH4.5
Pressure1 atm
Temperature (K)288
Experiment(s):2D NOESY, DQF-COSY
Sample ContentsAcetate buffer
Solvent100% D2O
Ionic Strength0.02
pH4.5
Pressure1 atm
Temperature (K)288
Experiment(s):2D NOESY
Spectrometer Information
Manufacturer Model Field Strength
Bruker AVANCE 800.0
Bruker AVANCE 500.0
NMR Refinement
Method Semi-automated calculation based on a set of ARIA runs.
Details No NOE peaks were manually assigned - calculation is based on initial NOE peak lists and chemical shift assignments combined with ambiguous restraints used in ARIA.
NMR Ensemble Information
Conformer Selection Criteria structures with the lowest energy
Conformers Calculated Total Number 30
Conformers Submitted Total Number 10
Representative Model Choice Rationale
1 lowest energy
Computation: NMR Software
# Classification Software Name Author
1 refinement ARIA 1.0 Linge
2 processing XWINNMR 2.1 Bruker