X-RAY DIFFRACTION Experimental Data & Validation


X-ray Experimental Help

Crystal Data

Unit Cell
Length (Å) Angle (°)
a = 63.4 α = 90
b = 63.4 β = 90
c = 83.9 γ = 120
Symmetry
Space Group P 61

Diffraction

Diffraction Detector
Detector Diffraction Type Details Collection Date
AREA DETECTOR SIEMENS -- 1993-12-08
Diffraction Radiation
Monochromator Protocol
-- --
Diffraction Detector Source
Source Type Wavelength List Synchrotron Site Beamline
-- -- -- -- --

Data Collection

Overall
Resolution (High) Resolution (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
-- -- 94.0 0.095 -- -- -- -- 8051 -- -- --

Refinement

Statistics
Structure Solution Method Refinement High Resolution Refinement Low Resolution Cut-off Sigma (I) Cut-off Sigma (F) Number of Reflections (All) Number of Reflections (Observed) Number of Reflections (R-Free) Percent Reflections (Observed) R-Factor (All) R-Factor (Observed) R-Work R-Free R-Free Selection Details
-- 2.3 10.0 -- 2.0 -- 6831 -- 80.9 -- 0.177 -- -- --
RMS Deviations
Key Refinement Restraint Deviation
p_bond_d 0.018
p_angle_d 3.55
Number of Non-Hydrogen Atoms Used in Refinement
Non-Hydrogen Atoms Numbers
Protein Atoms 1516
Nucleic Acid Atoms 0
Heterogen Atoms 42
Solvent Atoms 33

Software

Computing
Computing Package Purpose
XENGEN Data Reduction (intensity integration)
X-PLOR Structure Solution
PROLSQ, X-PLOR Structure Refinement
Software
Software Name Purpose
X-PLOR refinement
PROLSQ refinement
X-PLOR model building